Code Block |
---|
cd ..
cd psa_images/semifield_tools/
screen -R <batch_name>
python3 copy_from_lockers_test.py <batch_name> |
Semifield batches can take anywhere from a few minutes to half an hour to copy over, depending on the batch size. It is important to open a new screen for copying. Only to copy one or two batches at a time within their respective screens to avoid disk space problems.
...
Example: MD_2024-07-02
Code Block |
---|
ls /mnt/research-projects/s/screberg/longterm_images2/semifield-upload/MD_2024-07-02/*.ARW | wc -l |
output: 560
Code Block |
---|
ls /home/psa_images/temp_data/semifield-upload/MD_2024-07-02/*.ARW | wc -l |
output (before running the pipeline): 560
output (after running the pipeline): 0
Code Block |
---|
ls /mnt/research-projects/s/screberg/longterm_images2/semifield-developed-images/MD_2024-07-02/images/*.jpg | wc -l |
output (after running the pipeline): 560
Trouble shooting:
If developed jpgs are not in the longterm storage, check to see if they’re still in the local temp_data outputs folder:
Check for jpgs:
Code Block |
---|
ls /home/psa_images/temp_data/semifield-outputs/MD_2024-07-26/images/*.jpg | wc -l |
check for same number of .pp3 files (how you know they’ve been developed):
Code Block |
---|
ls /home/psa_images/temp_data/semifield-outputs/MD_2024-07-26/images/*.pp3 | wc -l |
If they’re both present and have the same number, we know they’ve been successfully preprpocessed, but may not have been successfully move to the longterm locker storage location.
If there is an “Assertion Error”, try going into RawTherapee, and create & save the profile again.
2. Color Profiling in RawTherapee
...
Exposure Compensation & Highlight Compression
These two go hand-in-hand. Exposure compensation should always be set to slightly more than Highlight Compression
Lightness
Has a similar effect to Exposure Compensation
Saturation
Toggle keeping in mind the intensity of colors on the color checker.
3. Running the pipeline
...
** Don't run >3 batches in the pipeline at once. This applies to both Semifield and Field combined. **
Profiling can be done and batches can be prepared for the pipeline, but wait to run them until another batch finished.
After the color profile has been saved, send it through the pipeline. Be sure to be navigated to the Semifield folder and make a new screen, use uppercase r (-R). If returning to an already existing screen, use lowercase r (-r) with the appropriate screen name.
...